Troubleshooting Malfunctions (Cent)
TROUBLESHOOTING INSTRUCTIONS
12-15.
2-9. Troubleshooting
Malfunction
Test or Inspection
Corrective Action
HEAVY-DUTY WINCH
1.1.
WINCH CABLE WILL NOT PAY OUT
)
NOTE
Batteries must be disconnected.
Step 7. Disconnect connector from winch OUT solenoid. Set all electrical switches for remote
operation (TM 9-2320-279-10). Check resistance of wire 682 from contact 2 on winch OUT
connector to pin B at electrical control box.
If resistance is more than zero ohms, repair wire 682 or replace winch out
connector<
Step 8. Check wires in remote control cable for continuity.
If resistance is more than zero ohms, repair wire or replace connector.
If problem remains, notify the supervisor.