TM
9-2320-279-20-1
Troubleshooting Malfunctions (Cont)
TROUBLESHOOTING INSTRUCTIONS (CONT).
12-15.
2-9. Troubleshooting (Cont)
Table
Malfunction
Test or Inspection
Corrective Action
AIR SYSTEM (CONT)
4.
NOISY COMPRESSOR OPERATION.
Step 1. Check air discharge line for kinks and restrictions.
Remove line and clear restriction or replace air discharge line (para 11-23).
Step 2. If problem has not been solved, replace compressor (para 11-38).
COMPRESSOR CYCLES CONSTANTLY.
5.
Step 1. Check connections, lines, and components for leaks.
Tighten loose connections and repair leaking lines (para 11-23).
Replace components as necessary (go to Alphabetical Index to find component
replacement procedure).
Step 2. Check for defective governor.
Adjust governor (para 11-36).
If governor cannot be adjusted, replace governor (para 11-37).
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |