Table 2-2. Unit Level Preventive Maintenance Checks and Services
Item
Interval
Item To Be
Procedure
Not Mission
No.
Inspected
Capable If:
M1977-
CBT,
M1120
LHS Only
59.1
Semi-
Self-
Check self-guided coupler (1) for cracks, dam-
Radial  wear  exceeds
Annual
Guided
age, or excessive wear. Replace coupler if
3/16 in. (4.76 mm).
Coupler
cracked or damaged. If radial wear exceeds
3/16 in. (4.76 mm) total, replace coupler before
next mission. If axial clearance exceeds 1/32
in. (.79 mm), measure thickness of washer (2).
If washer (2) thickness is under 3/16 in. (4.76
Washer thickness is less
mm), replace washer. If washer thickness is
than 3/16 in. (4.76 mm).
larger than 3/16 in. (4.76 mm), adjust nut (3).
Refer to Para 14-15.01.
If circumference at worn area of coupler jaw
Circumference at worn
(4) is less than 8-1/2 in. (215.9 mm), replace
area is less than 8-1/4 in.
coupler at next scheduled service. If circum-
(209.6 mm).
ference is less than 8-1/4 in. (209.6 mm), re-
place coupler before next mission. Refer to
Para 14-15.01.