Click here to make tpub.com your Home Page

Page Title: Table 2-2. Unit Level Preventive Maintenance Checks And Services-continued
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-279-20-1
Table 2-2. Unit Level Preventive Maintenance Checks And Services
Item
Interval
Item To Be
Procedure
Not Mission
No.
Inspected
Capable If:
M984Al
Crane
Continued
52 Annual
Crane
Check oil at fill plug. Add oil (GO) as re-
Hoist
quired at fill hole.
Drive
DRAlN PLUG
53
Annual
Turntable
Check all turntable bearing screws for
Screws  will not
Bearing
torque to 370 lb-ft
looseness. If loose, tighten screws to 370
Screws
(502 Nm).
lb-ft (502 Nm
2-48.18 Change 2

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business