Table 2-1. Unit Level Preventive Maintenance Checks and Services
Not Mission
Procedure
Item To Be
Interval
Item
Capable If:
Inspected
No
NOTE
M977 and
M985
Load testing of cranes is required before initial
Crane
use of all new cranes, cranes that have been
extensively repaired, cranes that have under-
gone modification or alteration, and cranes
that have remained idle six or more months.
Crane does not meet load
Refer crane to next higher level of mainte-
test requirements.
nance for load testing.
NOTE
Lift Cylin-
Semi-
1
der Pivot
Annual
Purging of lubricant.
When using a grease gun, apply lubricant to
the fitting until clean lubricant squeezes out
of the fitting being lubricated.
Fittings will not purge
Lubricate both ends of lift cylinders with GAA.
old lubricant out of com-
ponent.