TM 9-2320-211-34-2-4
Assembly.
e.
FRAME 1
WARNING
Contact
cement is flammable. Do not use near an open
K e e p a fire extinguisher nearby when contact
flame.
is used, U s e only in well-ventilated places.
cement
Failure
to do this may result in injury to personnel and
damage
to equipment.
NOTE
If insulation panels are damaged, do steps 1 and 2. If
i n s u l a t i o n panels are not damaged, go to frame 2.
P u t each insulation panel in place before putting on con-
t a c t cement to be sure panel is in the proper position.
P u t a coat of contact cement on six panels (1 through 4).
1.
Press two rear insulation panels (1) into place. Press two rear side insulation
2.
p a n e l s (2) into place. P r e s s rear bottom center insulation panel (3) into place.
P r e s s rear top center insulation panel (4) into place.
GO TO FRAME 2
|