TM 9-2320-211-34-2-4
g.
Replacement.
FRAME 1
WARNING
S m o k i n g , sparks or open flames are not allowed within
5 0 feet of work area during this task. Fuel can explode,
c a u s i n g injury to personnel and damage to equipment.
1.
W o r k i n g in battery box, put heater assembly (1) into two retainer clamps (2).
C l o s e and screw tight two retainer clamps (2).
P l u g in and screw on tight electrical connector (3).
2.
3.
Slide exhaust pipe elbow (4) onto heater (1). Put in cotter pin (5). Bend
over ends of cotter pin (5).
4.
P u t fuel line (6) on fuel control valve (7). Screw on and tighten fitting (8).
5.
T u r n on fuel cock (9).
NOTE
Follow-on Maintenance Action Required:
1.
P u t on coolant hoses at heater. Refer to
T M 9-2320-211-20.
2.
P u t on battery ground strap. Refer to
T M 9-2320-211-20.
3.
O p e r a t e heater and check for coolant and fuel
l e a k s . R e f e r to TM 9-2320-211-10.
END OF TASK
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |