b.
Removal.
FRAME 1
WARNING
Smoking, sparks or open flames are not allowed within
5 0 feet of work area during this task. Fuel can explode,
c a u s i n g injury to personnel and damage to equipment.
1.
W o r k i n g in battery box, shut off fuel cock (1).
2.
U n s c r e w fitting (2) and pull fuel line (3) from fuel control valve (4).
3.
T a k e out cotter pin (5) and slide off exhaust pipe elbow (6) from heater (7).
U n s c r e w and unplug electrical connector (8) from heater (7).
4.
5.
U n s c r e w and open two heater retainer clamps (9) and take out heater
assembly (7).
END OF TASK