TM
9-2320-211-34-2-3
FRAME 2
Check that poppet (1) does not bind in cover and guide (2).
1.
Check that poppet (3) does not bind in body (4).
2.
I f b i n d i n g i s f o u n d , t h r o w away relief valve and get a new one in its place.
3.
Check that valve poppets (1 and 3) and their seating faces in bores of
4.
I f damage is
relief valve (5), do not have grooves, scratches, or pits.
m a j o r , throw away relief valve and get a new one in its place.
WARNING
Dry cleaning solvent is flammable. Do not use
n e a r an open flame.
Keep a fire extinguisher
n e a r b y w h e n s o l v e n t i s u s e d . U s e only in well-
v e n t i l a t e d p l a c e s . F a i l u r e to do this may result
in injury to personnel and damage to equipment.
E y e shields must be worn when using compressed
air. Eye injury can occur if eye shields are not
used.
Using lapping compound, lap poppets (1 and 3) against their seating faces.
5.
Be very careful to keep poppets centered in bores of relief valve.
U s i n g solvent, wash away all traces of lapping compound. Dry with com-
6.
pressed air.
GO TO FRAME 3
NOTE
CHECK ONLY THOSE PARTS WHICH ARE CALLED OUT,
PARTS WITHOUT CALLOUTS ARE SHOWN ONLY FOR
REFERENCE PURPOSES.
17-635
|