TM 9-2320-211-34-2-2
d.
Cleaning.
There are no special cleaning procedures needed. Refer to clean-
ing
procedures
given in Part 1, p a r a 1 - 3 .
NOTE
Clean all parts b e f o r e inspection and after repair.
Inspection
and
Repair.
1.
C h e c k that two hinge halves (1) have no cracks or worn hinge pin holes. Weld
c r a c k e d h i n g e ha l f . R e f e r t o T M 9 - 2 3 ' / .
Check that hood side panel (2) has no dents, bends or cracks. Straighten
2.
bends and dents. Refer to FM 43-2. Weld cracks. Refer to TM 9-237.
3.
C h e c k that two latches (3) work freely without binding. If latches are
d a m a g e d , get new ones.
C h e c k that retainer clip (4) has no cracks or broken ends.
4.
END OF TASK
|