Inspection.
FRAME 1
1.
C h e c k that base (1) and subbase (2) are not cracked.
2.
C h e c k that walking beam (3) is not cracked and that bores are not out-of
round, pitted or scored.
3.
C h e c k that two pivot pins (4) are not pitted, grooved or broken.
4.
C h e c k that two coupler jaws (5) do not have rounded edges and that bores
are not out-of-round.
5.
C h e c k that stud (6) is not bent or worn, and that it has no damaged threads.
6.
C h e c k that locking plunger latch (7) is not bent or worn.
7.
C h e c k that base shaft (8) and subbase shaft (9) are not pitted, grooved or
cracked.