TM 9-2320-211-34-2-2
c.
C l e a n i n g , Inspection, and Repair.
WARNING
D r y cleaning solvent is flammable. Do not use near
an open flame. Keep a fire extinguisher nearby when
s o l v e n t is used. Use only in well-ventilated places.
Failure to do this may result in injury to personnel
and damage to equipment.
(1) Cleaning.
Clean parts in solvent.
( 2 ) Inspection and Repair. C h e c k that bumper, upper reinforcing gussets, and
l o w e r reinforcing gussets are not cracked, broken or bent. Repair by
s t r a i g h t e n i n g or welding. Refer to TM 9-237.
d.
Replacement.
FRAME 1
Hold lower reinforcing gusset (1) in place.
1.
2.
Put in screw (2) and nut (3).
3.
Hold upper reinforcing gusset (4) in place.
4.
Put in screw (5) and nut (6).
Do steps 1 through 4 again to put on upper reinforcing gusset (7) and lower
5.
r e i n f o r c i n g gusset (8).
GO TO FRAME 2
|