Disassembly.
c.
FRAME 1
CAUTION
Be careful when taking out brass fittings. If fittings are
damaged, they can cause damage to hydraulic pump.
1.
Unscrew nut (1) on hose (2). Take off hose.
2.
Take out elbows (3 and 4).
3.
Take out elbow (5) by taking out adapter (6) from pump (7). Take off and throw
away preformed packing (8).
4.
Take off reducer (9) from elbow (5).
GO TO FRAME 2
|