TM 9-2320-211-34-2-2
FRAME 2
1.
C h e c k that end plate (1) is not cracked or distorted and that threads are
n o t damaged. If end plate is damaged, get a new one.
2.
C h e c k that fitting (2) is not corroded or scored, and that threads are not
d a m a g e d . Using micrometer, check that bore of fitting is between 1.2505 and
1 , 2 5 2 0 inches. If fitting is damaged or not within given limits, get a new one.
C h e c k that stem (3) is not corroded or damaged in any way. Using no. 00
3.
s t e e l wool, take off corrosion. If stem is damaged, get a new one.
C h e c k that spring (4) is not damaged. Using ruler, check that free length
4.
o f spring is 3 1/2 inches. If it is not this length, get a new one.
P u s h down on spring (4) until it is 1 9/32 inches high and let it go back to
5.
i t s full height. Measure spring length again. If it is not 3 1/2 inches, get
a new one.
GO TO FRAME 3
11-34
|