TM 9-2320-211-34-2-1
FRAME 5
NOTE
Readings must be within limits given in table 9-3. If
r e a d i n g s are not within given limits, throw away parts
a n d get new ones.
1.
M e a s u r e outside diameter of differential spider (1).
2.
M e a s u r e inside diameter of spider bushing (2).
3.
M e a s u r e fit between differential spider (1) and spider bushing (2).
GO TO FRAME 6
NOTE: CHECK ONLY THOSE PARTS WHICH ARE CALLED OUT.
PARTS WITHOUT CALLOUTS ARE SHOWN ONLY FOR
REFERENCE PURPOSES.
Differential Spider Assembly Wear Limits
Size and Fit
Wear Limit
of New Parts
(inches)
(inches)
Item /Point of Measurement
Index Number
Differential spider
1
None
1 . 1 2 3 to 1.122
o u t s i d e diameter
Spider bushing
2
None
1 . 1 2 7 to 1.129
i n s i d e diameter
None
0 . 0 0 9 to 0.007
Spider to bushing
1 and 2
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |