TM 9-2320-211-34-2-1
Cleaning.
e.
( 1 ) Clean all bearings. Refer to para 7-7.
WARNING
Dry cleaning solvent is flammable. Do not use near an open
flame. Keep fire extinguisher nearby when solvent is
used. Use only in well-ventilated places. Failure to do this
may result in injury to personnel and damage to equipment.
(2) Clean all other parts with solvent.
WARNING
Eye shields must be worn when using compressed air.
Eye injury can occur if eye shields are not used.
(3) Make sure all oil passages are open. Open clogged passages with compressed
air or by working a wire back and forth. Flush with solvent.
|