FRAME 3
NOTE
Readings must be within limits given in table 7-2. If
readings are not within given limits, throw away both gears
and get new ones.  S o m e gears on countershaft cannot
be taken off. If these gears are damaged, throw away
counter shaft and get a new one.
Measure backlash between second speed gear (1) and countersha.ft second speed
1.
gear (2).
Measure backlash between second speed gear (1) and synchronizer (3).
2.
Measure backlash between synchronizer (3) and second and third speed clutch
3.
gear (4).
Measure backlash between second and third speed clutch gear (4) and main shaft (5).
4.
GO TO FRAME 4
TA 087359
Transmission Second Speed Gear Backlash Wear Limits
Size and Fit
Wear Limit
of New Parts
Item/Point of Measurement
Index Number
(inches)
(inches)
1 and 2
None
S e c o n d speed gear to counter-
0 . 0 0 6 to 0.009
shaft second speed gear
1 and 3
0 . 0 0 4 to 0.009
None
S e c o n d speed gear to synchron-
izer
0 . 0 0 4 to 0.007
3 and 4
None
S y n c h r o n i z e r to second and
third speed clutch gear
4 and 5
0 . 0 0 0 to 0.003
None
S e c o n d and third speed clutch
gear to main shaft