TM 9-2320-211-34-2-1
c.
Inspection and Repair.
FRAME 1
1.
P l u g all openings in tank (1) except one.
Put in air hose and put 6 psi of air
p r e s s u r e into tank. Listen for air leaks.
WARNING
Do not repair unless tank has been cleaned and properly
t r e a t e d to get rid of all inflammable or explosive fumes.
M e r e l y draining tank does not make it safe for welding.
A n "empty" tank can be more dangerous than a full one.
B e f o r e repairing, thoroughly steam clean tank or use
o t h e r approved method to completely take out all fumes.
2.
Weld small leaks. Refer to TM 9-237. If tank (1) has a large
leak, get a new
tank.
C h e c k that filler cap (2) and filler sleeve (3) are not cracked or dented. If
3.
c a p or sleeve is damaged, get a new one.
4.
C h e c k that filler cap gasket (4) is not worn or dried out. If gasket is worn
o r dried out, get a new one.
C h e c k that drain plug (5) has no damaged threads. If plug has damaged
5.
t h r e a d s , get a new one.
END OF TASK
|