WARNING
Dry cleaning solvent is flammable. Do not use
near an open flame. Keep a fire extinguisher
nearby when solvent is used. Use only in well-
ventilated places. Failure to do this may result
in injury to personnel and damage to equipment.
Eye shields must be worn when using compressed
air. Eye injury can occur if eye shields are not
used.
d. Cleaning and Inspection.
(1) Wash all parts in solvent. Let parts dry.
(2) Blow out tube and ports with compressed air.
(3) Check all parts for cracks, stripped threads, or other damage. If parts
are damaged, tell direct support maintenance.
e. Assembly.
FRAME 1
1.
Screw in filler cap (1).
2.
Using wrench, screw in and tighten elbow (2).
Screw in and tighten plastic tube (3) into strainer body (4).
3.
Put gasket (5) into strainer body (4) and screw in and tighten glass jar (6).
4.
END