TM 9-2320-211-20-3-1
Cleaning Filter.
c.
1.
l-inch wrench, unscrew and take out cap nut (1).
Using
2,
Take out cup strainer (2), lambs wool (3), and cylinder
strainer (4).
WARNING
Dry cleaning solvent is flammable. Do not use near an
open flame. Keep a fire extinguisher nearby when sol-
vent is used. Use only in well-ventilated places. Fail-
ure to do this may result in injury to personnel and
damage to equipment.
3.
Clean lambs wool (3) and strainers (2 and 4) with dry cleaning solvent.
4.
Soak lambs wool (3) with lubricating oil and put it inside cylinder strainer
(4).
Put strainer (4) with lambs wool (3) in body ( 5).
5.
Put cup strainer (2) in body (5). Using l-inch wrench, screw on cap
6.
nut (1).
END OF TASK
|