TM 9-2320-211-20-3-1
Disassembly and Service.
c.
Using wrench, unscrew and take out two capscrews (1).
1.
Take off cap (2) and take out spring (3), plate (4), strainer (5) and
2.
gasket (6). Throw away gasket.
WARNING
Dry cleaning solvent is flammable. Do not use near an
open flame. Keep a fire extinguisher nearby when sol-
vent is used. Use only in well-ventilated places. Fail-
ure to do this may result in injury to personnel and
damage to equipment.
Eye shields must be worn when using compressed air.
Eye injury can occur if eye shields are not used.
3.
Using solvent , wash strainer (5). Blow compressed air through strainer
to make sure it is clean.
END OF TASK
|