TM 9-2320-211-20-3-1
(c) Air tube elbow.
CAUTION
Fittings are made of soft brass and can be
stripped easily if tightened too much.
Tighten fittings just enough to stop air from
leaking.
NOTE
The air tube elbow on the air reservoir is used
for this typical task.
Screw elbow (1) into tee fitting (2).
1.
Using 3/4-inch
open end wrench , hold nut (2)
2.
q
Using 10-inch pipe wrench, tighten elbow (1).
3.
Using 5/8-inch combination box and open end wrench, screw on and
4.
tighten tube nut (3).
NOTE
Follow-on Maintenance Action Required:
1.
Start engine and let it run until air pressure gage
reads between 65 and 120 psi. Refer to
TM 9-2320-211-10.
Stop engine. Refer to TM 9-2320-211-10.
2.
3.
Do air system leak test. Refer to Para 1-5.
Replace tool box. Refer to Part 2, para 17-11.
4.
END OF TASK
12-130
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |