TM 9-2320-211-20-3-1
Cleaning.
b.
FRAME 1
WARNING
Dry cleaning solvent is flammable. Do not use near
an open flame. Keep a fire extinguisher nearby when
solvent is used. Use only in well-ventilated places.
Failure to do this may result in injury to personnel
and damage to equipment.
1.
Soak relief valve (1) in solvent.
2.
Using wire brush, brush all dirt from relief valve (1).
Clean passage (2) and make sure valve cap (3) moves freely.
3.
WARNING
Eye shields must be worn when using compressed
air. Eye injury can occur if eye shields are not used.
4. Dry relief valve (1) with compressed air and use small amount of lubricating
oil to lubricate.
END OF TASK
|