TM 9-2320-211-20-3-1
FRAME 4
Push front generator flange (1) tightly against front bracket flange (2).
1.
2.
Slip 0.005-inch feeler gage between rear generator flange (3) and rear
bracket flange (4). Gage should slide in very easily.
Holding up rear of generator (5), pull screw (6) out of rear generator flange
3.
(3).
Slip needed number of shims (7) between rear generator flange (3) and rear
4.
bracket flange (4). Push screw (6) back through rear generator flange (3).
5.
Push rear generator flange (3) tightly against shims (7).
6.
Slip 0.005-inch feeler gage between front generator flange (1) and front
bracket flange (2).
7.
If feeler gage fit is not snug, do steps 3 through 6 again.