TM 9-2320-211-20-3-1
Replacement.
c.
FRAME 1
Dry cleaning solvent is flammable. Do not use near an
open flame. Keep a fire extinguisher nearby when solvent
is used. Use only in well-ventilated places. Failure to do
this may result in injury to personnel and damage to
equipment.
NOTE
Before putting in water pump (1), clean it well with
solvent. Make sure till mating surfaces are smooth
and free of dirt.
1. Slide water pump (1) into hose (2) and aline screw holes in water pump with
holes in engine block (3).
2. Using 9/16-inch wrench, screw in and tighten three screws (4) with
lockwashers (5).
GO TO FRAME 2
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |