TM 9-2320-211-20-3-1
b.
Removal.
WARNING
Smoking, sparks or open flame are not allowed
within 50 feet of work area during this task.
Fire or explosion could occur, causing injury to
personnel and damage to equipment.
FRAME 1
Place container under filter housing (1).
1.
2.
Using wrench, unscrew and take out drain plug (2).
3.
When all fuel has drained from filter housing (1), using wrench, unscrew and
take off nut (3).
4.
Pull off filter housing cover (4) and take out gasket (5). Throw away gasket.
5.
Pull filter element (6) out of filter housing (1). Throw filter element away.
6.
Take out container. Put fuel in approved disposal area.
WARNING
Dry cleaning solvent is flammable. Do not use near an
open flame. Keep a fire extinguisher nearby when sol-
vent is used. Use only in well-ventilated places. Fail-
ure to do this may result in injury to personnel and dam-
age to equipment.
7. Clean filter housing (1) with solvent.
END OF TASK
|