TM 9-2320-211-20-3-1
Replacement.
b.
WARNING
Smoking, sparks or open flame are not allowed
within 50 feet of work area during this task. Fire
or explosion could occur, causing injury to person-
nel and damage to equipment.
Put filter element (1) into filter housing (2).
1.
2. Put gasket (3) in place and put on filter housing cover (4).
3. Using 7/8-inch wrench, screw in and tighten nut (5).
4. Using 3/4-inch wrench, screw in and tighten drain plug (6).
NOTE
Follow-on Maintenance Action Required:
1. Bleed air from fuel system. Refer to para 4-17.
2. Close hood. Refer to TM 9-2320-211-10.
END OF TASK