Removal.
b.
FRAME 1
Place container under filter housing (l).
1.
2.
Using 1 l/8-inch wrench, unscrew and takeout drain plug (2).
3.
When all fuel has drained from filter housing (1), using 7/16-inch wrench, un-
screw and take off four nuts (3).
4.
Pull down filter housing (1) and take out gasket (4). Throw away gasket.
5.
Pull filter element (5) out of filter housing (1).
Take out container. Put fuel in approved disposal area.
6.
WARNING
Dry cleaning solvent is flammable. Do not use near an
open flame. Keep a fire extinguisher nearby when sol-
vent is used. Use only in well-ventilated places. Fail-
ure to do this may result in injury to personnel and dam-
age to equipment.
7.  Clean filter element (5) and filter housing (1) with solvent.
END OF TASK