4-4. FUEL TRANSFER PUMP REMOVAL AND REPLACEMENT.
Smoking, sparks, or open flame are not allowed
within 50 feet of work area during this task.
Fuel could catch fire or explode, causing serious
injury to personnel and damage to equipment.
TOOLS:  7/16-inch wrench (2)
5/8-inch wrench
3/4-inch wrench
l/2-inch wrench (2)
SUPPLIES:  None
PERSONNEL: One
EQUIPMENT CONDITION: Truck parked, engine off, handbrake set.
a.  Preliminary Procedure. Disconnect battery ground cable. Refer to para 7-44.