Replacement.
c.
FRAME 1
NOTE
Put avery thin coating of liquid gasket cement on all
fuel line fitting threads before putting fittings in place.
Take off cover from opening in fuel tank (1).
1.
WARNING
Dry cleaning solvent is flammable. Do not use near an
open flame. Keep a fire extinguisher nearby when solvent
is used. Use only in well-ventilated places. Failure to
do this may result in injury to personnel and damage to
equipment.
2.
Clean mating flanges of fuel supply pump (2) and fuel tank (1) with solvent.
Put gasket (3) on fuel tank mounting flange (4), dining holes.
3.
4.
Carefully put fuel supply pump (2) into fuel tank (1). Do not scrape pump
against edges of fuel tank opening. Damage to electrical cable shield on pump
could cause electrical failure.
5.
Turn fuel supply pump (2) so fittings are in positions noted.
TO FRAME 2
GO