TM55-1730-215-13 & P
d. Disassembly. (AVIM)
(1) Remove stop nut (1, figure 3-5) and plunger wiper (2).
(2) Remove plunger (3) and spacer (4) from cylinder (11).
(3) Dissamble plunger assembly by removing stop nut (5),
spreader (6), grommet (7), plunger cap (8), disk (9), and O-Ring
(10)
q
e. Cleaning. (AVIM)
Perform solvent cleaning operations in
an approved cleaning cabinet or in a
well-ventilated area. Keep dry clean-
ing solvent away from sparks and
flames. Avoid prolonged breathing of
vapors. Avoid eye and repeated skin
contact. Use approved personnel pro-
tective equipment (eye goggles/face
shield/gloves) when handling solvents
or using compressed air. Provide pro-
tection from flying particles when
using compressed air. Do not direct
airstream towards self or other
personnel.
Clean disassembled parts with dry cleaning solvent (item 4,
Appendix D), and dry with clean, lint-free cloth.
f. Inspection and Repair (AVIM).
(1) Inspect O-ring (10,
plunger cup (8), grommet (7) and
spreader (6) for evidence of
tearing, swelling, nicks or other
defects which may cause leaking.
Replace all defective parts.
(2) Inspect cylinder (11)
for pitting, scoring,
roughness.
(3) Lightly hone cylinder to
recondition if possible. If
pitting or scoring is too deep
to hone out, replace cylinder.
3-27
|