TM55-1730-215-13 & P
OPERATING INSTRUCTIONS
Section I
DESCRIPTION AND USE OF OPERATOR CONTROLS
2-1. Moving the Platform.
a. The platform should be
positioned in the desired
location before raising.
NOTE
The swivel casters are
equipped with spring
loaded lock pins. When
engaged, these lock the
casters in 90 degree
increments.
b. When preparing to position
the platform, unlock the casters
on all four wheels, and release
the brakes on the two rear
casters.
c. When in position lock the
casters and set the brakes.
a. Remove both safety lock
pins (1). Stow pins.
CAUTION
Failure to open and
close the vent plug
as prescribed will
result in failure of
the hydraulic pump,
gasket and seals.
b. Open vent plug (2).
c. Close the release valve
(3).
d. Operate pump handle (4)
until platform reaches the
desired height.
e. Reinstall safety lock pins
(1).
f. Close vent plug (2).
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |