TM 55-1510-218-MTF
PROCEDURE
TROUBLESHOOTING
REFERENCE
(1) Cabin temperature mode
selector switch (C-12C, C-
12D) and C-12F prior to se-
rial number 86-60084) -
OFF.
(2) Cabin air mode selector
switch (C-12F after serial
number 86-60084) - OFF.
(3) Electrical Ioad - Reduce to
minimum.
(4) Fire pull handle - In.
(5) Power Iever - IDLE.
(6) C o n d i t i o n l e v e r - F U E L
CUTOFF.
(7) TGT (operating engine) -
700C or less.
(8) Ignition and engine start
switch - ON.
(9) C o n d i t i o n l e v e r - L O W
IDLE.
(10) TGT - 1000C. 5 seconds
maximum.
(11) Ignition and engine start
switch - OFF at 50% N1 .
(12) Generator switch - RESET,
then ON.
(13) Engine cleanup - Perform if
engine restart is unsuccess-
ful.
(14) Cabin temperature mode
selector switch (C-12C, C-
12D and (C-12F prior to se-
rial number 86-60084) - As
required.