PROCEDURE
REFERENCE
ABORT START
1.
Condition
lever
-
FUEL
CUTOFF.
2. Ignition and engine start switch -
STARTER ONLY.
3. TGT - Monitor for drop in temper-
ature.
4. Ignition and engine start switch -
OFF.
ENGINE CLEARING
1. Condition lever - FUEL CUTOFF.
2. Ignition and engine start switch -
OFF (1 minute minimum).
Do not exceed starter limitation of 40 sec-
onds on and 60 seconds off for two starting
attempts and engine clearing procedure. Al-
low 30 minutes off before additional starter
operation.
3. Ignition and engine start switch -
STARTER ONLY (15 seconds
minimum, 40 seconds maximum).
4. Ignition and engine start switch -
OFF.
2-21