TM
55-1510-218-MTF
PROCEDURE
TROUBLESHOOTING
REFERENCE
SECOND ENGINE START (BATTERY
START) (CONT)
A1-8
FUEL PRESS light should extin-
guish.
4 . C o n d i t i o n l e v e r ( a f t e r N1 R P M
passes 12% minimum) - LOW
IDLE.
5. First engine generator switch - RE-
SET, then ON.
6 . T G T a n d N1 - M o n i t o r . T G T
1000C maximum, N1 5 2 % m i n i -
mum (C-12C and C-12D), or N1
56% minimum (C-12F).
7. Oil pressure - Check (60 PSI mini-
E7-9
mum).
8. Ignition and engine start switch -
OFF after TGT stabilized.
9. Battery charge light - Check. Light
should illuminate approximately 6
seconds after generator is brought
on line. Light should extinguish
within 5 minutes following a nor-
mal engine start on battery).
10. Inverter switches - ON. Check IN-
VERTER lights extinguished.
11. Second engine generator switch -
RESET, then ON.
12. Strobe beacon light switch - DAY
or NIGHT as required.
13. Condition levers - As required.
2-20
|