TM
55-1510-218-MTF
PROCEDURE TROUBLESHOOTING
REFERENCE
BEFORE STARTING ENGINES (CONT)
DOOR (if open), and REV
NOT
READY
caution
lights.
b. Annunciator test switch - Press
and hold. Check that all lights
in both annunciator panels,
FIRE
PULL
handle
lights,
marker
beacon
lights,
MAS-
TER CAUTION and MASTER
WARNING lights are illumi-
nated.
Release
switch
and
check that all lights except
those in step (a) are extin-
guished.
c.
Master caution and master
warning lights - Press and re-
lease. Both lights should extin-
guish.
C29,40-
*31.
Stall and gear warning
system
-
41
Check as follows:
a. Stall and landing gear warning
test switch - Lift to STALL
WARN TEST postion. Check
for warning horn tone and V i -
sually check for stall warning
vane movement.
b. Stall and landing gear warning
horn test switch - Set to LDG
GEAR WARN TEST position.
Check for warning horn tone
and that the red LDG GEAR
CONTR handle warning lights
(2) illuminated.
C49-51
*32. Fire protection system (C-12C, C-
12D, and C-12F aircraft prior to C-
12F serial number 86-60084) -
Check as follows: