TM 5-5420-279-23
(10)
Repeat step 5.
(11)
Remove the pump and connect to the hydraulic connection point (7) on the pre-loaded
valve (8).
(12)
Pump hydraulic fluid into the reservoir (2) until the center section of the reservoir is full.
NOTE
Step 13 is only required when changing the hydraulic oil for climatic or cold conditions.
(13)
Using a suction pump, remove the hydraulic oil in the reservoir (2).
(14)
Fill up the reservoir (2) until oil just covers the filter.
NOTE
A baffle plate separates the three compartments and oil can transfer between
compartments should one compartment overfill.
(15)
Replace the reservoir filler cap (1).
b.
Follow on task
(1)
Check the operation of the far bank support in accordance with the operator's manual TM
5-5420-279-10.
5-253
|