TM 5-5420-279-23
All Maintainer Tasks
Crane
keeps switching to
overload
Connect a hydraulic pressure
gauge to the pressure gauge
test point at the crane valve
control block
Is
the gauge reading
Replace crane valve control
working pressure 4496 psi
block see m aintenance
No
(31000 kPa) when the crane
procedure 6-073
controls are
operated
Yes
Check and adjust if
necessary the settings
at the pressure
transducer, see
m aintenance procedure
6-084
Is
End of trouble
fault
Yes
shooting
rectified
No
Replace
pressure transducer. see
m aintenance procedure
6-084
|