TSUM - 2-029 Upper Winch Function Check Part 2
Part 2
All Maintainer
Tasks
Does
Go to
gauge read 3191 psi
No
Part 4
(22000 kPa)
Yes
Fit pressure gauge to TPB2
on Launch Fram e Pilot
Manifold. Operate joystick to
pay out
Manually operate
Does
solenoid valve SV6 on
Does
Go to
Launch Fram e Pilot
gauge read 588 psi
No
gauge read 588 psi
No
Part 3
Manifold and operate
(4000 kPa)
(4000 kPa)
joystick to pay out
Yes
Yes
Check winch for m echanical fault or
Replace solenoid
jam m ing, see -10 chapter 9. If required
coil on SV6 on Launch Fram e
replace upper winch assem bly.
Pilot Manifold. See m aintenance
See m aintenance procedure 6-017
procedure 5-124