TM 5-5420-279-23
Left Hand Stabilizer leg
does not retract
Is
stabilizer leg pin
Yes
Rem ove pin
inserted in transit
hole
Operator
Tasks
No
Maintainer
Tasks
Fit a Pressure Gauge to TPA1
on Stabilizer Manifold
Manually operate A-Fram e Stabilizer leg
control valve on A-fram e stabilizer Leg
Manifold, to retract leg and observe
pressure gauge
Is
Greater than 500 psi (3500 kPa)
pressure gauge
Zero
with no leg m ovem ent
reading
Stop m anual
Stop m anual
Less than 500 psi (3500 kPa)
operation of the
operation of the
A-Fram e Stabilizer
A-Fram e Stabilizer
leg control valve
leg control valve
Stop m anual
operation of the
A-Fram e Stabilizer
leg control valve
Replace A-Fram e
Mechanical jam in stabilizer leg
Fit pressure
Stabilizer leg control
m echanism .
gauge to TPB1 on
valve. See m aintenance
Refer to -10 Chapter 9 step 110
Stabilizer Manifold
procedure 5-127
Manually operate A-Fram e
Stabilizer leg control valve to
retract leg and observe
pressure on gauge
Go to
Part 2
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |