TM 5-5420-279-23
TSUM - 2-021 Bridge Return High Bank Part 4
All Maintainer Tasks
W ith joystick
operated to carriage
Part 4
in - m anually operate
No
line 1
SV8 on Launch
Fram e Pilot Manifold
Does
gauge read
No
363 psi (2500
kPa)
Yes
Fit pressure
gauge to TPP2 on
Replace solenoid
Launch Fram e
coil on SV8. See
Pilot Manifold
m aintenance procedure
5-124
Replace 363 psi
Does
Replace SV8
(2500 kPa) pressure
gauge read
valve assem bly. See
Yes
reducing valve. See
No
363 psi (2500
m aintenance
m aintenance procedure
kPa)
procedure 5-122
5-130, item 5
Fit pressure
W ith joystick operated to
gauge to TPPB on
Carriage In - m anually
Part 4
Launch Fram e
operate solenoid valve
No
Line 2
W inch Control
SV15b on Launch Fram e
Manifold
W inch Control Manifold
Replace Back
Tension pressure
Does
No
gauge read
reducing valve. See
Operate joystick to
No
m aintenance
1015 psi (7000
Carriage In
kPa)
procedure 5-132,
item 5
Does
gauge read
1015 psi (7000
Yes
kPa)
Yes
Replace valve assem bly SV14
Replace solenoid
on Launch Fram e W inch Control
coil SV15b. See
Manifold See m aintenance
m aintenance
procedure 5-122
procedure 5-124
|