TM 5-5420-279-23
TSUM - 2-004 Extend LH Stabilizer Leg (21) Part 2
Part 2
Stop m anual operation
of the A-Fram e
Stabilizer leg control
valve
Fit pressure gauge to
TPA1 on Stabilizer
m anifold
Manually operate A-Fram e
Stabilizer leg control valve to
retract leg and observe
pressure on gauge
Does
Increase without
Show no pressure
pressure gauge
any leg extension
change
reading
Stop m anual operation
Stop m anual operation
of the A-Fram e
of the A-Fram e
Stabilizer leg control
Stabilizer leg control
valve
valve
Replace A-Fram e Stabilizer
Leg Control Stack Valve. See
hydrauiic trouble shooting
Replace Stabilizer leg cylinder (LH).
chapter 2 procedure 2-031 &
See m aintenance procedure 6-003
m aintenance procedure
5-128
|