TM 11-6625-601-34
frequency selector, through contacts 2 and 4 of
the right homer antenna, and the center con-
ductor of the coaxial cable, to plug P2. From
switch S11A (front), contacts 6 and 5 of switch
plug P2, ground is applied to COAX CONT
S10A (front), pin A of jack J10, and pin A of jack
RIGHT lamp DS10, causing the lamp to light.
J101, to the CU-942/ARC-54 or CU-943/ARC-54.
The MHz ambiguity select A control line routes
1-6. Signal Path of Test Set, Radio TS-
f r o m the unit MHz ambiguity frequency
1 9 6 7 / A R C - 5 4 Connected to Coupler,
selector, through contacts 2 and 4 of switch
Antenna CU-942/ARC-54 or CU-943/
S11E (front) contacts 2 and 1 of switch S10B
ARC-54
(front), pin F of jack J10, and pin F of jack J101,
t o the CU-942/ARC-54 or CU-943/ARC-54.
The test set contains a frequency selection con-
M e g a h e r t z ambiguity select B control line
routes from the unit megahertz ambiguity fre-
trol system, a dummy load, and operating vol-
tage for testing the CU942/ARC-54 or
quency selector, through contacts 8 and 10 of
CU943/ARC-54. The frequency selection con-
switch S11A (front), contacts 2 and 1 of switch
trol system includes two groups of coded control
S10A (front), pin G of jack J10, and pin G of jack
lines. One group contains five control lines,
J101, to the CU942/ARC-54 or CU-943/ARC-54.
b. Operating Voltage and Dummy Load.
labeled MHz select A through E, and the other
group contains two control lines, labeled MHz
Operating voltage of +27.5 volts dc is applied
from the test set, through pin J of ANT
ambiguity select A and B. The RT-348/ARC-54,
normally connected to the CU942/ARC54 or
COUPLER jack J10 and pin J of jack J101, to
CU-943/ARC-54, is simulated by the dummy
the CU-942/ARC-54 or CU943/ARC-54. The
load.
dummy load (antenna coupler load AT2) is con-
n e c t e d f r o m t h e t e s t s e t , t h r o u g h ANT
a. Frequency Selection Control Lines.
Megahertz select control lines A through E and
COUPLER LOAD jack J15 and jack J103, to the
megacycle select ambiguity control lines A and
CU-942/ARC-54 or CU-943/ARC-54.
B, coded for the desired frequency in the unit
1-7. Signal Path of Control, Radio Set
MHz frequency selector, are applied to the tun-
C-3835/ARC-54 Connected to TS-
ing
circuit in
the
CU-942/ARC-54 or
1 9 6 7 / A R C - 5 4 and SM-349/ARC-54
CU943/ARC-54. The tuning circuit operates
t h e drive motors in the CU942/ARC-54 or
CU-943/ARC-54 until the desired frequency has
The test set, and simulator check the operating
been reached. The MHz select A control line
functions of the C4835/ARC-54. These func-
routes from the unit MHz frequency selector,
tions include frequency selection, squelch con-
through contacts 2 and 4 of TEST FUNCTION
trol, and homing operation. An indicator on the
SELECTOR switch S11A (rear), contacts 11 and
test set provides a visual check of the homing
10 of TEST FUNCTION SELECTOR, switch
circuit. A readout counter in the simulator dis-
the
selection by
the
frequency
plays
S10A (rear), pin E of ANT COUPLER jack J10,
and pin E of jack J101, to the CU942/ARC-54
C-3835/ARC-54. An indicator on the simulator
or CU943/ARC-54. The MHz select B control
checks the operation of the squelch control cir-
line routes from the unit MHz frequency
cuit.
selector, through contacts 8 and 10 of switch
On
the
a. Frequency
Test.
Selection
S11B (front), contacts 5 and 4 of switch S10B
simulator, t h e F R E Q U E N C Y M C r e a d o u t
(rear), pin D of jack J10, and pin D of jack J101,
counter, ODD MC lamp DS11, EVEN MC lamp
to the CU-942/ARC-54 or CU-943/ARC-54. The
DS12, and HAR FIL lamp DS2 give visual indi-
megahertz select C control line routes from the
cations of the operation of the frequency selec-
unit MHz frequency selector, through contacts
tor circuit in the C-3835/ARC-54. The frequency
11 and 1 of switch S11A (front), contacts 5 and
selected by the C-3835/ARC-54 is indicated on
4 of switch S10A (rear), pin C of jack J10, and
the FREQUENCY MC readout counter. Setting
pin C of jack J101, to the CU-942/ARC-54 or
the frequency selector switches on the
CU-943/ARC-54. The MHz select D control line
C-3835/ARC-54 to a specific frequency codes the
routes from the unit MHz frequency selector,
unit and fractional MHz control wires. This
through contacts 5 and 7 of switch S11B (front),
coded information is applied to motor control
contacts 6 and 5 of switch S10B (front), pin B
unit A2 in the simulator. The motor control unit
of jack J10, and pin B of jack J101, to the
rotates switches S4 and S5 and the counter until
CU942/ARC-54 or CU-943/ARC-54. The MHz
the selected frequency appears in the window
select E control line routes from the unit MHz
of the FREQUENCY MC readout counter. The
1-4
|