TM 11-6625-601-12
3-7. Visual Inspection
3 . 8 . Quarterly Preventive Maintenance
Checks and Services
a. When the equipment fails to perform properly,
turn off the power and check all the items listed
Perform the maintenance function indicated in the
below.
quarterly preventive maintenance checks and
Warning:
services chart (para 3-9) in addition to those given
Do not check any item with the power on.
in the daily and monthly preventive maintenance
Damage to personnel from high voltage
checks and services charts (para 3-4 and 3-6). A
exists when the power is turned on.
quarterly interval is defined as approximately 90
(1) Check to see that the switches and controls
calender days of 8-hour-per-day operation. Ad-
have been set properly.
justment of the maintenance interval must be
(2) Check to see that the power and rf jumper
m a d e for any unusual operating conditions.
cables are connected properly.
Equipment used less than 8 hours per day or
(3) Check to see that the power circuit breaker
maintained in a standby (ready for immediate
on the TS-1967/ARC-54 is on.
operation) condition requires quarterly preventive
6. If the checks in a above do not locate the
maintenance. Equipment in limited storage (re-
trouble, perform the procedures given in the
quires service before operation) does not require
troubleshooting chart.
quarterly preventive maintenance.
3-9. Quarterly Preventive Maintenance Checks and Services Chart
WARNING
3-10. Cleaning
The fumes of TRICHLOROETHANE are
Inspect the exterior of the MK-733/ARC-54. The
t o x i c . Provide thorough ventilation
exterior surfaces should be free of dirt, grease, and
whenever it is used; avoid prolonged or
fungus.
repeated breathing of vapor. Do not use
a. Remove dust and other loose dirt with a clean.
n e a r an open flame or hot surface;
soft cloth.
3-4 Change 3
|