TM 1-1510-223-MTF
PROCEDURE
TROUBLESHOOTING
REFERENCE
FIRST ENGINE START (BATTERY START) (CONT)
CAUTION
If ignition does not occur within 10 seconds after moving
CONDITION lever to LOW IDLE, initiate Abort Start
procedure. If for any reason a starting attempt is discontinued,
the entire starting sequence must be repeated after allowing
the engine to come to a complete stop (1 minute minimum).
6.
CONDITION lever (after N1 RPM
passes 13% minimum) - LOW IDLE.
CAUTION
Monitor TGT to avoid a hot start. If there is a rapid rise in
TGT, be prepared to abort the start before limits are exceeded.
During starting, the maximum allowable TGT is 1000 for 5
C
seconds. If this limit is exceeded, initiate Abort Start
procedure and discontinue start. Enter the peak temperature
and duration on DA Form 2408-13-1.
7.
TGT and N! (TGT 1000 Maximum).
C
8.
Oil pressure - Check (60 PSI minimum).
9.
# 2 ENG START switch - OFF after TGT peaks.
10. CONDITION lever - HIGH IDLE.
Monitor TGT as CONDITION lever is
advanced.
11. # 2 GENERATOR switch - RESET, then ON.
2-34
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |