TB 9-2320-279-34
Test Classification Ill is a static Iift test used to assure structural integrity of HIAB Cranes at 110
percent of their maximum rated load.
Test Classification IV is a dynamic functions test performed to assure operability of crane and
outriggers. All cranes are tested at 100 percent of their maximum rated load. The HIAB 8108
Crane dynamic testing is at 110 percent of the load rating.
Crane Model
Load Rating (pounds)
Load Radius
(Feet' and Inches")
Grove M977
4,500
9'
Grove M984
(on M984E1)
14,000
9'
Grove M985
5,400
16'6"
HIAB 8108 & 8108-2
On M985E1
4,500
20'6"
HIAB 8109
10,000
12'
(on M984)
Test toads for HEMIT Cranes may take the form of weights that are locally fabricated, or any
available item of the proper weight. (The weight of any lifting slings, hooks or rigging should be
considered in selecting or instructing test weights). A calibrated load indicator or a calibrated
dynamometer may be used for static testing. All load testing devices should have a valid
calibration label affixed in a visible place. If a calibrated dynamometer is used, be sure it has a
minimum capacity of twice the load test value for proper accuracy.
unique fabrication details are given, Table 2-4 gives weight details for bulk plate steel of varying
thickness. If weights are constructed by welding plates together, allowance should be made for
additional weight added by the welding process.
Change 2
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |