TB 43-0002-34
planation of cost factors to be considered when computing repair cost esti-
direct labor costs, direct material costs, and other charges that are applicable
to the repair of the Item. Results of the technical inspections, recorded on DA
Form 2404, are transferred to Section II, DA Form 2407.
c. Report of unserviceable excess stock on SF 359 (Billing Adjustment/
Allowance Card) will be accompanied by inspection, or report on DA Form
ment covered by this bulletin is eligible for evacuation to depot whenever the
3590 in three copies.
technical inspection performed at general support level Indicates that repairs
d Request for disposition instructions will be prepared in accordance with
required are not authorized and/or exceed their capability or maintenance ex-
AR 755-1. Attention IS called to reporting requirements for both CONUS
penditure limits listed herein.
and oversea installations in AR 755-1, for all principal items of equipment.
10. Disposition Instructions.
e. Equipment will not be reported for disposition solely on the basis that it
IS overage. Serviceable overage equipment will be retained in use, unless
a. Field Commanders are authorized to waive repair expenditure limits
priority of organization's mission warrants a replacement. Repairs to over-
under the conditions and within the limits established in AR 750-1
age equipment will be limited to the maintenance necessary to maintain it
in a safe, operable condition.
b. When the estimated one-time repair cost exceeds the prescribed ex-
penditure limits and waiver of limits IS not authorized as provided for by
paragraph 4-12, AR 750-1, no action will be taken to dispose of the equip-
ment until disposition instructions are received from the NICP.
Section VI. APPENDIXES
e. Column 5. Serial Number Range or USA Number. The serial number
determining repair eligibility. The equipment listings contain only those end
ranges for the production years listed in column 4.
items that are known to be in hands of troops or depot stock. All items are
f. Column 6. Years of Life Expectancy. FSC Class 5430-Appendix C, rigid
identified by National Stock Number and are arranged in numerical sequence.
type metallic tanks normally are issued as Class IV items and therefore the
These listings are not to be used as an identification list of all items assigned
life expectancy is indefinite. The life expectancy for collapse type tanks
to the FSC classes indicated. For complete identification of FSC Group 54 ma-
is as shown.
terial, refer to the appropriate supply catalogs (II).
B, and C are as follows:
a Column 1. FSC or Stock Number. End item National Stock Number
listed in numerical sequence.
13. References.
b. Column 2. Item Identification. Item generic nomenclature, functional ca-
pability, make and model.
c. Column 3. Serial or USA Number Identification and Remarks. This col-
4
A