Click here to make tpub.com your Home Page

Page Title: AIR PRESSURE TEST
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2320-366-20-3
AIR PRESSURE TEST
AIR PRESSURE TEST (Cont)
(26) Remove STE/ICE-R 0-1000 PSI transducer
NOTE
from output port of regulator valve.
Tag air hoses and connection points prior
(27) Apply sealing compuond to threads of pipe
to disconnecting.
nipple.
(1) Disconnect air hose from adapter fitting on
(28) Install regulating valve on pipe nipple.
shuttle valve.
(29) Install 30K winch tension Pneumatic
(2) Disconnect air hose from 90 degree fitting
valve assembly (para 17-30).
on shuttle valve.
(30) Close LH and RH catwalks.
(3) Remove two self-locking nuts, washers,
screws, and shuttle valve from bulkhead.
Discard self-locking nuts.
(4) Position shuttle valve in vise.
(5) Remove regulator valve from pipe nipple.
(6) Install STE/ICE-R 0-1000 PSI pressure
transducer in output port of regulator valve.
(7) Connect input air hose to input 90 degree
fitting of regulator valve.
(8) Start engine (TM 9-2320-366-10-1) and
allow vehicle to build air pressure.
(9) Perform STE/ICE-R Test #50 and note
reading on STE/ICE-R.
(10) If 55-65 PSI (380-440 kPa) is not present,
perform step (18) through (22).
(11) If 55-65 PSI (380-440 kPa) is present,
replace shuttle valve (para 17-30).
(12) Shut down engine (TM 9-2320-366-10-1).
(13) Drain air tanks (TM 9-2320-366-10-1).
(14) Disconnect input air hose from output 90
degree fitting of regulator valve.
(15) Remove STE/ICE-R 0-1000 PSI transducer
from output port of regulator valve.
(16) Close LH and RH catwalks.
NOTE
Perform step (17) for M1089 RH 30K
winch cable drum tensioner.
(17) Install M1089 control panel covers
(para 17-20).
(18) Pull out and turn knob on regulator valve
fully counter clockwise.
(19) Pull out and turn knob on regulator valve
clockwise until STE/ICE-R shows between
55-65 PSI (380-440 kPa).
(20) If 55-65 PSI (380-440 kPa) is present after
adjustment, perform steps (23) through (30).
(21) If 55-65 PSI (380-440 kPa) is still not present
after adjustment, replace regulator valve
(para 17-30).
(22) Perform steps (12) through (17).
(23) Shut down engine (TM 9-2320-366-10-1).
(24) Drain air tanks (TM 9-2320-366-10-1).
(25) Disconnect input air hose from input 90
degree fitting of regulator valve.
Change 1

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business