Electrical System Maintenance Instructions (Cont)
TLI TANK LEVEL INDICATOR GAGE AND BRACKET REMOVAL/
INSTALLATION (M978) (TWO STUDS ON BACK OF INDICATOR GAGE).
This task covers:
a. Removal
c. Follow-on Maintenance
b. Installation
INITIAL SETUP
Models
References
M978 (with two studs on back of TLI tank
None
level indicator gage)
Equipment Condition
Test Equipment
TM or Para
Condition Description
None
TM 9-2320-279-10 Pump module rear access
doors opened.
Special Tools
Batteries disconnected.
None
Supplies
Special Environmental Conditions
Tags, identification, Item 48, Appendic C
None
Compound, sealing, pipe thread, Item 18,
Appendix C
Adhesive-sealant, silicone, Item 4, Appendix C
General Safety Instructions
Personnel Required
No smoking, flame, sparks, and hot or glowing
MOS 63S, Heavy wheel vehicle mechanic
objects within 50 ft (15 m) of vehicle.
a.
Removal.
(1)
Remove six screws (1), cover (2), and gasket (3) from junction box (4).