TM 9-2920-225-34
d. Tachometer Calibration Information. Find the speed of generator using the
following formula:
(Y) = Diameter of test stand drive pulley.
1.
Place DC AMMETER LOAD AND STARTER selector (1) in 150A position.
Set DC AMMETER FIELD AND BATTERY CHARGER selector (2) in 5A
2.
I
position.
Make sure that DC VOLTMETER RANGE selector (3) is in 50V position.
3.
Make sure that DC VOLTMETER CIRCUIT selector (4) is in RECT /GEN
4.
position.
Set FIELD CIRCUIT switch (5) to REGULATOR position.
5.
GO
TO FRAME 2
q
TA 103719